Home / Products / Water filter element / high flow filter cartridge /

Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment
Parker High Flow Filter for Industrial Ultrafiltration Pretreatment

Parker High Flow Filter for Industrial Ultrafiltration Pretreatment

Parker high flow filter is a large‑diameter pleated consumable engineered for industrial ultrafiltration pretreatment workflows. This liquid filter delivers high single‑unit throughput and stable particle interception performance for heavy‑duty water‑treatment projects via optimized pleat structure design. It may cooperate with POV102UNPFA high flow filter cartridge and PFTM1060UHFH1 high flow filter cartridge to capture silt, suspended solids and colloidal pollutants, providing reliable upstream protection for downstream ultrafiltration membrane assemblies. This filter stabilizes feed‑water quality and may assist facility operators to lower potential ultrafiltration membrane fouling risks.

Parker High Flow Filter for Industrial Ultrafiltration Pretreatment

Parker high flow filter is a large‑diameter pleated consumable engineered for industrial ultrafiltration pretreatment workflows. This liquid filter delivers high single‑unit throughput and stable particle interception performance for heavy‑duty water‑treatment projects via optimized pleat structure design. It may cooperate with POV102UNPFA high flow filter cartridge and PFTM1060UHFH1 high flow filter cartridge to capture silt, suspended solids and colloidal pollutants, providing reliable upstream protection for downstream ultrafiltration membrane assemblies. This filter stabilizes feed‑water quality and may assist facility operators to lower potential ultrafiltration membrane fouling risks.

Product Introduction

Long‑term stable operation of ultrafiltration membrane modules is heavily subject to feed‑water pretreatment performance, and Parker high flow filter acts as a widely adopted pleated consumable within this critical pretreatment link. This filter adopts enlarged outer dimension to expand total effective filtration area, bringing outstanding single‑unit flow capacity for large‑scale industrial water‑treatment facilities. Its matched end‑cap structure fits compatible Parker‑series high‑flow filter housings, supporting quick installation and convenient component replacement during routine on‑site maintenance. Benefiting from its strong single‑unit throughput, fewer filter units are required to satisfy total system flow demands, which may ease spare‑part inventory pressure for end‑users.

In practical water‑treatment engineering projects, system designers frequently deploy this filter alongside Large Flow Micro Hole Folding Water Filter Element to build multi‑grade pretreatment sequences before raw‑water flows into ultrafiltration membrane vessels. Parker high flow filter mainly adopts high‑purity virgin polypropylene filter media, delivering favorable chemical compatibility for most neutral industrial water‑treatment environments. Thermal‑fusion welding connects filter media and end‑caps instead of liquid adhesive, reducing possible risks of adhesive leaching into process water. Within recommended pressure and temperature operating ranges, filter media tends to minimize fiber shedding, which may cut down scratch and contamination hazards for high‑cost ultrafiltration membranes.

For EPC contractors, water‑plant operators and system integrators, Parker high flow filter fits both new‑construction water‑treatment projects and spare‑part replenishment scenarios. When original‑brand lead times cannot match project construction schedules, dimension‑compatible alternative filter units can be selected to keep project progress on track. Its well‑optimized structural layout helps shrink overall system footprint and saves installation space for water‑treatment skid assemblies.

high flow pleated filter cartridge

Working Principle

Parker high flow filter applies radial pleated depth‑filtration working mechanism. Raw‑water enters filter housing and contacts outer pleated surfaces of the filter. Fluid flows radially from outer pleated layers toward inner central core through multi‑layer polypropylene filter media. Solid particles, silt, iron‑oxide sediments, colloids and suspended impurities are trapped on both surface and inner depth layers of filter media. Treated water flows out from inner central core and transfers onward to downstream ultrafiltration equipment.

The large‑diameter radial pleated design maximizes effective filtration area under fixed housing inner dimension. As the system keeps running, intercepted contaminants accumulate gradually and raise differential pressure value between filter inlet and outlet. When differential pressure reaches recommended threshold, on‑site operation teams can perform filter‑replacement operations. This filtration mode purely relies on physical interception; no chemical additives are introduced into process water, and core water chemical properties will not go through major changes.

Within a complete ultrafiltration workflow, Parker high flow filter serves as front‑line protective barrier for ultrafiltration membranes. It removes most coarse contaminants in advance, eases pollutant load accumulated on membrane surfaces and lowers particle‑caused scratch possibilities. When designing pretreatment sequences, users may match this filter with High Flow Water Filter Element to realize multi‑stage graded filtration. Such configuration can further reduce operation burden of ultrafiltration modules and support longer continuous system‑running cycles.

Technical Parameters

ItemSpecification
ModelParker high flow filter
Filter MediaPolypropylene (PP), radial large‑diameter pleated structure
Nominal Micron Rating1‑20 μm (optional)
Common Length40 / 60 inch
InterfaceSpecial end‑cap for Parker‑series high‑flow filter housing
Single Unit Max Flow RateUp to 110 m³/h (subject to raw‑water quality)
Maximum Operating Temperature60 ℃
Max Suggested Differential Pressure3.4 bar
Chemical CompatibilitySuitable for most neutral aqueous solutions
Typical ApplicationUltrafiltration pre‑filtration, RO security filtration

Quality Assurance

Each Parker high flow filter goes through standardized production procedures and multi‑level quality inspection checkpoints. Virgin‑grade polypropylene raw materials are adopted in production to maintain stable filter‑media performance. Multiple inspection items including bubble‑point testing, pressure‑cycle evaluation and fiber‑shedding verification are completed for finished units before shipment.

Thermal‑welding technology connects filter media and end‑caps, pursuing stable bonding performance under regular water‑treatment operating conditions. Strict dimensional inspection is implemented to guarantee fitting compatibility with matched high‑flow filter housings. Batch‑wise production records are retained for traceability purposes.

Sample filter units are tested under simulated industrial water‑treatment operating conditions. Long‑time high‑flow cycle tests help assess structural stability in common application scenarios. Products comply with widely‑accepted industrial water‑treatment component standards. Properly selected and maintained filter units may help reduce unplanned system downtime and bring optimized operating costs for end‑users.

Parker high flow filter

Application Fields

Parker high flow filter is mainly deployed for ultrafiltration system pre‑filtration protection, covering multiple industrial sectors:

  1. Industrial Pure‑Water Production: Pre‑filtration for ultrafiltration units inside electronics, food and beverage manufacturing plants, intercepting silt and granular impurities to safeguard ultrafiltration membrane modules.

  2. Municipal Water Reuse Project: Pretreatment for municipal reclaimed‑water ultrafiltration processes, coping with large‑volume raw‑water containing high suspended‑solid content.

  3. Seawater Desalination Pretreatment: Used as front‑end security filtration matched with ultrafiltration devices, lowering pollutant burden for subsequent processing stages.

  4. Pharmaceutical & Cosmetic Process‑water System: Removing granular impurities from process water to satisfy pretreatment demands for preparation‑water ultrafiltration.

  5. Mine and Industrial Wastewater Recycling: Filtering recycled wastewater before ultrafiltration recovery steps, which may mitigate membrane fouling frequency.

  6. Industrial‑park Centralized Water Supply: Pre‑filtration for large‑scale centralized ultrafiltration water‑supply systems.

Users can adjust configuration schemes according to raw‑water quality and project budget. For heavily polluted incoming water, multi‑stage graded filtration setup is recommended to potentially extend filter service cycles. For high‑purity process‑water projects, finer‑precision filter grades can be chosen.

FAQ

Q1: Which filter housings are compatible with Parker high flow filter?

A: This filter is designed for Parker‑series high‑flow filter housings. Please confirm filter length, micron rating and housing inner dimension before placing orders.

Q2: What core role does Parker high flow filter undertake in ultrafiltration systems?

A: It delivers ultrafiltration pre‑filtration protection. It captures suspended solids, silt and colloidal contaminants, reduces pollutant load reaching ultrafiltration membranes, and may slow down membrane fouling to extend membrane service cycles.

Q3: What factors will affect the service life of Parker high flow filter?

A: Service cycle is mainly influenced by raw‑water quality and actual operating flow rate. It is suggested to replace the filter when inlet‑outlet differential pressure reaches 2.5‑3.4 bar. Poor‑quality raw water tends to shorten service time.

Q4: Besides ultrafiltration pretreatment, can Parker high flow filter be applied for reverse osmosis security filtration?

A: Yes. It can act as security pre‑filter for large‑scale reverse osmosis projects. Confirm suitable micron rating according to your RO membrane operating requirements.

Q5: Is parallel installation of multiple Parker high flow filter units allowed within one filter housing?

A: Yes, multiple units can be installed in parallel within matched high‑flow housings to raise overall system flow capacity. Housing quantity and filter quantity should be calculated based on project design flow rate.

Q6: What is the recommended maximum continuous working temperature for this polypropylene filter?

A: Recommended maximum continuous operating temperature is 60 ℃. Long‑time operation above this temperature may deform polypropylene filter media and weaken filtration performance.

Other products you may want to know about:

 high flow filter cartridge

self-cleaning filter

cartridge filter housing


Get a FREE Quote

RELATED PRODUCTS

Leave a message

If you want to get more details about filter and filtration equipment, you can send E-mail to filter01@lefilter.com. You can consult our professional engineer and specialized sales team with leave a message in below form. We will contact with you ASAP. You also can visit our factory in Henan China.