Parker Cartridge Filters MFNP050‑40N‑ITT for UF Pretreatment
Parker Cartridge filters MFNP050‑40N‑ITT serves as a critical pretreatment component for industrial ultrafiltration systems. This liquid filter delivers high‑capacity particle holding capability and reduces frequent filter element replacement cycles. Constructed with high‑strength pleated polypropylene medium, it fits standard large‑flow filter housings and works compatibly with High‑flow water filter cartridge and Water Filtration PP Pleated Filter to build complete multi‑stage water treatment workflows. It is widely adopted for process water purification in power, chemical and food‑beverage industries across global markets.
Product Introduction
Parker Cartridge filters MFNP050‑40N‑ITT is a large‑diameter high‑flow pleated filter cartridge specially designed for ultrafiltration pretreatment protection. As a drop‑in alternative industrial filter element, it is installed on the front‑end of ultrafiltration membrane modules, mainly used for intercepting suspended solids, colloids, fine sediment, pipeline rust and granular impurities inside raw water. By removing most particulate contaminants in advance, it effectively suppresses UF membrane fouling risk, lowers membrane chemical cleaning frequency and extends the service life of expensive ultrafiltration membrane components.
Different from conventional small‑size filter cartridges, MFNP050‑40N‑ITT adopts large‑diameter pleated structural design, which greatly expands the effective filtration area of single filter element. Under the same working flow condition, fewer cartridges are required inside filter housing. For system integrators and end‑users, this helps cut filter‑housing quantity, reduce installation workload and lower long‑term operation‑maintenance expenses. When configuring the whole water treatment skid, users can match it with High Flow Pleated Filter Cartridge for Industrial UF System and Replace Pall Marksman High‑Flow Cartridge to realize gradient interception effect of multi‑grade pre‑filtration.
The whole filter cartridge adopts full polypropylene material construction. Thermal‑bond pleating technology replaces adhesive bonding, eliminating secondary pollution risk caused by glue dissolution under water flow scouring. End caps and inner‑outer support skeletons are integrally molded, maintaining stable structural performance under long‑term high‑flow impact and frequent pressure fluctuation. Whether for newly‑built ultrafiltration water‑making equipment or spare‑part replacement of existing water‑treatment production lines, Parker Cartridge filters MFNP050‑40N‑ITT can offer stable and consistent pretreatment filtering performance.

Working Principle
Parker Cartridge filters MFNP050‑40N‑ITT applies surface‑depth composite pleated filtration principle. After raw water enters filter housing, fluid flows radially from the outer surface of filter cartridge toward inner core. Large‑sized solid particles are firstly trapped on outer pleated surface layer, while tiny fine impurities go deep into polypropylene fiber gaps and get intercepted inside filter medium.
Large‑area pleated layout can distribute pollutants evenly across the whole filter medium, instead of contaminants accumulating only on partial local surface. This structural feature slows down pressure‑differential rising speed, maximizes dirt‑holding capacity and prolongs effective service cycle of filter cartridge. When the pressure difference between equipment inlet and outlet reaches preset threshold value, it means filter medium is fully loaded with intercepted pollutants, and operators need to replace the whole cartridge.
Acting as the front‑line protective barrier for ultrafiltration equipment, its core value is to undertake particulate impurity removal work. If raw water directly enters ultrafiltration membrane without this pretreatment protection, solid pollutants will deposit on membrane surface, block membrane pores, accelerate membrane fouling, increase chemical cleaning frequency, and even trigger irreversible membrane damage. When cooperating with PFTM11UNF high flow filter cartridge for multi‑stage combined filtration, the overall stability of water‑treatment system can be further improved. It should be noted that this filter element is only for solid‑particle interception, and cannot remove dissolved ions in water, so it only undertakes pretreatment work before ultrafiltration membrane.
Technical Parameters
| Item | Specification |
|---|
| Model | Parker Cartridge filters MFNP050‑40N‑ITT |
| Filtration Rating | 50μm nominal |
| Cartridge Length | 40 inch |
| Filter Media | Pleated Polypropylene (PP) |
| Support & End‑cap Material | Polypropylene |
| Outer Diameter | 152 mm |
| Inner Diameter | 63 mm |
| Single Cartridge Rated Flow | 110‑130 m³/h |
| Maximum Operating Temperature | 65℃ |
| Maximum Working Pressure | 1.0 MPa |
| Recommended Replacement Differential Pressure | 0.35 MPa |
| Connection Style | Special ITT interface |
| Chemical Compatibility | Excellent adaptability for neutral water, weak acid and weak alkali aqueous solution |
Quality Control
Every batch of Parker Cartridge filters MFNP050‑40N‑ITT will complete full‑process production inspection and finished‑product testing before delivery. Raw‑material incoming inspection is implemented for polypropylene filter cloth, support skeleton and end‑cap raw materials to guarantee raw‑material consistency. During production process, sampling inspection is carried out for pleating amplitude, thermal‑bond strength and end‑cap sealing performance.
Finished‑product testing covers bubble‑point integrity test, cyclic pressure impulse test and water‑flow pressure drop detection. Defective products with medium crack, poor sealing and structural looseness will be fully eliminated. Glue‑free thermal‑bond process avoids adhesive dissolution risk which would contaminate process water.
Products are manufactured in accordance with industrial filtration quality‑management specifications. Each filter cartridge is individually packed to prevent dust and particle contamination during storage and transportation. Complete technical datasheets are provided for engineering design reference. On‑site installation inspection is still required before putting into operation to confirm housing interface matching and sealing condition.

Application Fields
Parker Cartridge filters MFNP050‑40N‑ITT is mainly used as pretreatment filter for ultrafiltration water‑treatment systems, and it is also widely deployed in multiple industrial liquid‑filtration scenarios.
Industrial ultrafiltration system pretreatment: Trap sediment, iron‑oxide scale and suspended particles, protect UF membrane elements, reduce membrane cleaning frequency, suitable for raw‑water purification and circulating‑water treatment projects.
Power plant water treatment: Boiler make‑up water and condensate pre‑filtration, remove pipeline rust particles and suspended pollutants.
Food & beverage industry: Raw‑water pretreatment for drinking‑water and beverage production, filter granular impurities.
Chemical industry: Production process‑water filtration and circulating cooling water pretreatment.
Municipal water‑supply & reclaimed‑water reuse: Large‑flow raw‑water pre‑filtration for municipal water‑works and water‑recycling projects.
Pharmaceutical and cosmetic water‑making: Sanitary‑grade process‑water pre‑filtration for water‑preparation equipment.
According to actual raw‑water turbidity and pollutant composition of different projects, users can set multi‑stage gradient filtration to achieve better overall filtering effect.
FAQ
Q1: What role does Parker Cartridge filters MFNP050‑40N‑ITT play in ultrafiltration equipment?
A: It acts as ultrafiltration pretreatment protective filter. It intercepts suspended solids, sediment and granular contaminants inside raw water, reduces pollutant load on ultrafiltration membranes, slows down membrane fouling, cuts chemical cleaning frequency and extends UF membrane service life.
Q2: What is the service life of Parker Cartridge filters MFNP050‑40N‑ITT?
A: There is no fixed service‑life time standard. Service cycle is mainly determined by raw‑water turbidity, pollutant content and actual operating flow. Normally replace cartridge when inlet‑outlet differential pressure reaches 0.35 MPa.
Q3: Can Parker Cartridge filters MFNP050‑40N‑ITT be cleaned and reused after contamination?
A: This is disposable pleated filter element. After filter‑medium gaps are filled with pollutants, backwashing cannot fully restore original filtering performance. Re‑use after cleaning will bring particle leakage risk, direct replacement is recommended.
Q4: What kind of filter housing matches Parker Cartridge filters MFNP050‑40N‑ITT?
A: It adapts to 40‑inch large‑flow filter housing with special ITT connection interface. Before purchase, please confirm housing interface dimension, inner‑chamber space and pressure‑bearing rating to avoid installation mismatch.
Q5: Can MFNP050‑40N‑ITT work under strong‑acid and strong‑alkali working conditions?
A: Polypropylene material has good tolerance for weak‑acid and weak‑alkali aqueous medium. It is not fit for long‑term operation under high‑concentration strong‑acid or strong‑alkali environment. Please consult technical support for evaluation for special chemical‑medium working conditions.
Q6: How many pieces of MFNP050‑40N‑ITT cartridges do I need for my ultrafiltration system?
A: Quantity calculation depends on system total flow rate, single‑cartridge allowable flow and raw‑water quality. It is suggested to calculate required quantity referring to technical datasheet, and properly reserve surplus for fluctuating‑water‑quality working scenarios.
Other products you may want to know about:
Water filter element
Micro porous folded filter
PP melt-blown filter