Harmsco high flow filter cartridge, well-known as Hurricane series cartridge, is a classic pleated high-flow filter element widely adopted in municipal and industrial water purification. It features ultra-large filter area, low pressure drop and excellent contaminant holding capacity, commonly used for RO pre-treatment, cooling tower water and food beverage water filtration. Many water treatment engineers select this cartridge as a reliable fine filtration solution for graded filtration systems. This article covers product introduction, working principle, technical specifications, core advantages, application scenarios and FAQ, supporting you for filter skid design and element replacement.

Product Introduction

The Harmsco high flow filter cartridge is a premium pleated filter element from the Hurricane series, a mature and stable industrial water filter for a wide range of aqueous working conditions. This high flow filter cartridge can be assembled into high flow filter housings, and can work in series with a self-cleaning filter to form two-stage pretreatment, intercepting large debris first and then removing fine particles to extend cartridge service life. It adopts thermally integrated pleated structure with double O-ring sealing design, the media, center core and end cap are bonded into one piece to avoid bypass leakage. It provides multiple media options including polypropylene and polyester, with micron grades ranging from 0.35μm up to 150μm. With huge effective filtration area, one single cartridge can handle tremendous flow, greatly reducing the total quantity of filter cartridges and housings, cutting down installation space and maintenance workload. It is NSF certified for drinking water applications and compatible with standard Harmsco high flow filter housings.


Harmsco High Flow Filter Cartridge for Industrial Water Treatment


Working Principle

Harmsco Hurricane high flow cartridge mostly adopts up-flow filtration design. Raw water enters the filter housing tangentially, and the rotational flow helps separate heavy sediment before reaching the pleated media. Fine suspended particles, colloids and silt are trapped on the surface and inside the pleated layers. Clean water permeates the media and flows out from the central core. The special pleated structure keeps the media from compacting easily during operation, maintaining stable low differential pressure. When the inlet-outlet pressure difference rises to the preset threshold, the cartridge is saturated and needs replacement. When matched with a self-cleaning filter, coarse impurities are removed in advance, reducing the contaminant load on the Harmsco cartridge and prolonging service cycles.


Core Advantages

1. Large dirt holding capacity: 

Ultra-large pleated surface area captures more pollutants, longer service interval.

2. Low initial pressure drop: 

Stable flow performance, less pump energy consumption.

3. Integrated thermal bonding structure: 

No adhesive, avoid leakage and media shedding.

4. Rich media and micron options: 

PP, polyester available, adapt to acid, alkali, glycol and various aqueous solutions.

5. NSF certification: 

Safe for drinking water, bottled water and food contact water.

6. Up-flow cyclone assisted design: 

Pre-separate heavy sediment, reduce cartridge pollution speed.

7. Easy replacement: 

Standard interface, fast pull-out installation, short system downtime.


Technical Specifications

ItemParameter
SeriesHurricane HC Series
Media MaterialPolypropylene / Polyester-Plus™
Micron Rating0.35, 0.45, 1, 5, 10, 20, 50, 100, 150 μm
Surface Area4 / 40 / 90 / 170 sq.ft
Max Operating Pressure150 psi (1.0 MPa)
Max Temperature60℃ (CPVC housing); 93℃ (stainless steel housing)
SealingDouble O-ring
Flow DirectionUp-flow
Compatible HousingHarmsco HIF series high flow filter housing


Application Scenarios

Reverse osmosis and desalination system pre-filtration

Municipal raw water and drinking water purification

Cooling tower and chilled water loop filtration

Food, beverage and bottled water production water treatment

Marine, aquaculture and landscape water filtration

Industrial coolant, plating liquid and glycol solution filtration

Combined with self-cleaning filter and water filter housing for full graded pretreatment


FAQ

Q1: What is the unique feature of Harmsco Hurricane high flow cartridge compared with ordinary high flow cartridges? 

A: It matches the patented up-flow tangential inlet housing, which realizes preliminary cyclone sediment separation before media filtration, slowing down cartridge fouling.

Q2: Can it be used for drinking water?

A: Yes, selected models hold NSF certification, suitable for municipal drinking water and bottled water projects.

Q3: Can it work with self-cleaning filter?

A: Absolutely. The self-cleaning filter removes large floating matters, and the Harmsco cartridge undertakes fine particle filtration.

Q4: What chemicals can this cartridge resist? 

A: Polypropylene version fits most acid, alkali and aqueous solutions; polyester media is suitable for special industrial fluid filtration.

Q5: How to judge replacement time? 

A: Replace the cartridge when the differential pressure reaches 0.07–0.1 MPa.


Related Products

Equivalent ALN01-60B High Flow Cartridge for Ultrafiltration

RTM41HF050E High Flow Filter Element

3M High Flow Filter Cartridge

MFNP050‑40N‑ITT Cartridge Filters

Parker RCP100‑20EPP for Industrial Ultrafiltration Pretreatment

Get a FREE Quote

RELATED PRODUCTS

Leave a message

If you want to get more details about filter and filtration equipment, you can send E-mail to filter01@lefilter.com. You can consult our professional engineer and specialized sales team with leave a message in below form. We will contact with you ASAP. You also can visit our factory in Henan China.