Product Introduction
The HFU-1020AN Ultrafiltration (UF) Module is an industrial-grade membrane designed as a direct equivalent to the Toray HFU-1020AN module. Built for demanding municipal and industrial applications, this module offers precise water quality control, long-term reliability, and seamless system integration.
Constructed with top-tier hollow fiber membranes and housed in durable materials, the HFU-1020AN delivers excellent removal of suspended solids, bacteria, colloids, and high-molecular-weight organics. It supports critical functions such as potable water production, wastewater reuse, reverse osmosis (RO) pretreatment, and process water polishing—ensuring efficiency, cost-effectiveness, and sustainability.
 

Working Principle
The HFU-1020AN employs a proven outside-in ultrafiltration mechanism using hollow fiber membranes:
1.    Feed Water Introduction
 Raw or pretreated water enters the exterior of the fiber bundle inside the module.
2.    Selective Filtration
 Pressure pushes water through the membrane pore walls (nominal pore size ~0.03 µm), blocking suspended solids, bacteria, viruses, and colloids.
3.    Permeate Collection
 The filtered water flows through each fiber’s interior and is collected via the permeate manifold.
4.    Cleaning Protocol
 The system performs automated backwash and air scouring to dislodge retained contaminants. Periodic chemical cleaning-in-place (CIP) restores membrane performance.
This ensures continuous operation with consistent water quality, high recovery (>90%), and energy-efficient results, while preserving membrane integrity.
 

Key Features
1. Direct Toray Equivalent
Fully match in form, fit, and function with Toray HFU-1020AN, allowing for seamless replacement.
2. Robust Hollow Fiber Design
Manaufactured with precision to promote uniform permeability, mechanical strength, and long-term durability.
3. High-Quality Membrane Material
Makes use of PVDF or PES fibers—depending on application—to withstand harsh chemicals and maintain filtration performance.
4. Excellent Filtration Efficiency
Removes >99.99% of bacteria and >90% of high-molecular-weight organics, guaranteeing high-quality permeate.
5. Optimized Cleaning Capabilities
Supports backwash frequencies of 30–60 minutes and CIP cycles based on feed conditions, ensuring long-lasting performance.
6. Energy-Efficient Operation
Operates at low transmembrane pressures (TMP) between 0.1–0.3 MPa, reducing energy consumption.
7. Durable Module Housing
Available in materials like FRP, ABS, or PVC to suit various industrial conditions and chemical environments.
8. Scalable System Design
Compact and modular, it enables easy system expansion by adding more modules in parallel.
 

Technical Specifications
Parameter  | Specification  | 
Model  | HFU-1020AN UF Module – Toray Equivalent  | 
Membrane Type  | Hollow Fiber, Outside-In  | 
Membrane Material  | PVDF / PES  | 
Nominal Pore Size  | ~0.03 µm  | 
Permeate Area  | 100 m² per module  | 
Operating Temperature  | 5–40 °C  | 
Operating pH Range  | 4–10  | 
Cleaning pH Range  | 2–12 (Short-term 1–13)  | 
Transmembrane Pressure (TMP)  | 0.1–0.3 MPa  | 
Maximum Operating Pressure  | 0.4 MPa  | 
Backwash Cycle  | Every 30–60 minutes  | 
Air Scour Flow Rate  | 6–10 Nm³/h/module  | 
Connection Type  | Flange or Victaulic  | 
Housing Materials  | ABS, FRP, PVC  | 
Module Dimensions (L × Ø)  | ~1600 mm × 225 mm  | 
Service Life  | 5–7 years (under recommended conditions)  | 
Certification  | NSF/ANSI 61, ISO 9001  | 
 
Applications
1. Municipal Drinking Water Treatment
Removes turbidity, pathogens, and particulate matter to comply with drinking water standards.
2. Reverse Osmosis Pretreatment
Reduces SDI and particulate load, extending service life of sensitive RO membranes.
3. Industrial Process Water
Used in electronics, pharmaceuticals, pulp & paper, and food industries to ensure high-quality process water.
4. Wastewater Reuse
Acts as tertiary filtration to reclaim wastewater for utilities such as cooling, irrigation, or cleaning.
5. Desalination Pre-Treatment
Protects SWRO systems by eliminating particulates and microorganisms before desalination.
6. Cooling Towers & Boiler Feed Water
Reduces fouling and enhances thermal efficiency by removing suspended contaminants.
 

FAQ
Q1: Can I directly replace a Toray HFU-1020AN with this module?
 Yes. It is fully compatible in size, connections, and hydraulic performance—making swap-outs simple and quick.
Q2: What is the nominal pore size?
 Approximately 0.03 µm, suitable for retaining bacteria, viruses, and colloids.
Q3: What level of microbial removal can be expected?
 Achieves >99.99% bacterial log reduction and high virus rejection, depending on water quality.
Q4: How often does cleaning occur?
 Backwashing is typically triggered every 30–60 minutes, with CIP cycles determined by monitored pressure differentials.
Q5: What chemicals are used in CIP?
 Compatible with alkaline agents (NaOH), acid rinses (citric/phosphoric acid), and disinfectants (diluted NaOCl).
Q6: Is this module suitable for potable water systems?
 Yes—it meets NSF/ANSI 61 standards and is appropriate for municipal drinking water applications.
Q7: What is the membrane lifespan?
 Expect a service life of 5–7 years with proper maintenance and cleaning routines.
Q8: Is the module scalable for large systems?
 Yes. Modules can be operated in parallel to handle large flow rates and meet system demands.
 

Conclusion
The HFU-1020AN UF Module, as a Toray equivalent, offers industrial and municipal systems a reliable, cost-effective ultrafiltration solution. Featuring precise microbial control, low energy operation, robust build quality, and easy system integration, this module excels in applications ranging from drinking water treatment to industrial wastewater reuse.
Upgrade your system with this high-performance UF membrane to ensure consistent water quality, improve system longevity, and reduce operational costs—all while simplifying maintenance and installation.