Home / Products / Water filter element / Ultrafiltration Membrane Element /

CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent
CPI-1030 UF Module LITREE Equivalent

CPI-1030 UF Module LITREE Equivalent

LITREE CPI-1030 Industrial Grade UF Module Equivalent

Product Introduction

The CPI-1030 UF Module is a high-performance ultrafiltration membrane unit engineered to serve as a direct replacement for the LITREE CPI-1030 module. Designed for municipal, industrial, and commercial water treatment systems, this module is built around hydrophilic PVDF (polyvinylidene fluoride) hollow fiber membranes that provide outstanding mechanical strength, superior chemical resistance, and long-lasting filtration performance.

Fully compatible with the LITREE CPI-1030 in both form and function, this UF module offers easy integration into existing systems without retrofitting, ensuring a seamless transition while improving water quality and operational efficiency.

 

UltrafiltrationMembrane9.jpg


Working Principle

The CPI-1030 UF Module operates using the outside-in hollow fiber ultrafiltration method. It filters contaminants from feedwater by physically blocking particles larger than the membrane's pore size.

Filtration Process Overview:

1.    Feedwater enters the outside of the hollow fibers (shell side).

2.    Water permeates through the membrane wall, leaving behind particles, bacteria, and other suspended solids.

3.    Purified water collects inside the hollow fibers (lumen) and is directed to the permeate outlet.

4.    Regular backwashing and air scouring help dislodge accumulated foulants and maintain performance.

This physical separation process ensures a stable supply of high-quality water, even in the presence of challenging feedwater conditions.

 

UltrafiltrationMembrane21.jpeg


Key Features

·         Drop-in Replacement for LITREE CPI-1030
No changes needed to existing piping or support systems—plug-and-play design.

·         PVDF Hollow Fiber Membranes
Proven hydrophilic polymer provides exceptional fouling resistance and durability.

·         Effective Backwash & Air Scour Support
Extends operational life and reduces chemical cleaning frequency.

·         Excellent Flux and Low TMP
High permeability with consistent performance across variable operating conditions.

·         Reliable Bacterial & Turbidity Barrier
Removes over 99.99% of bacteria and provides turbidity reduction to <0.1 NTU.

·         Wide pH and Chemical Compatibility
Operates in acidic, neutral, and alkaline environments with strong chemical cleaning tolerance.

 

UltrafiltrationMembrane5.jpg


Technical Specifications

Parameter

CPI-1030 UF Module

Equivalent Model

LITREE CPI-1030

Membrane Material

PVDF (Hydrophilic)

Membrane Type

Hollow Fiber

Filtration Mode

Outside-In

Nominal Pore Size

0.03 µm

Effective Membrane Area

80 m²

Recommended Flow Rate

5.0 – 7.0 m³/h

Maximum Operating Pressure

0.3 MPa (3 bar)

Maximum Transmembrane Pressure

0.5 MPa (5 bar)

Operating pH Range

4 – 10

Cleaning pH Range

2 – 12

Operating Temperature Range

5°C – 45°C

Outer/Inner Fiber Diameter

1.3 mm / 0.7 mm

Housing Material

ABS / PVC-U

Backwash Support

Yes

Air Scour Support

Yes

Typical Lifespan

5 – 7 years

 

Applications

The CPI-1030 UF Module is suitable for a broad spectrum of water treatment processes, including:

1. Municipal Drinking Water Plants

Effectively removes pathogens and suspended solids to produce safe potable water.

2. Industrial Water Pretreatment

Prepares water for processes in power plants, electronics manufacturing, pharmaceuticals, food and beverage, etc.

3. Wastewater Reuse Projects

Polishes secondary effluent from sewage treatment plants for irrigation or industrial reuse.

4. RO and NF Pretreatment

Reduces SDI and microbial load to prevent fouling in downstream membranes.

5. Desalination Plant Pretreatment

Acts as a barrier against fine particles and microorganisms before seawater reverse osmosis systems.

6. Mobile Water Treatment Units

Perfect for containerized and mobile systems in remote or disaster-stricken areas.

 

UltrafiltrationMembrane3.jpg


FAQ

1. Is this module 100% compatible with the LITREE CPI-1030?

Yes, the CPI-1030 UF module matches the size, membrane area, and hydraulic connections of the original LITREE model, ensuring easy replacement.

2. What does this UF module remove from water?

It removes suspended solids, bacteria, algae, viruses, colloids, and other impurities down to 0.03 μm in size. However, it does not remove dissolved salts or organics.

3. How often should the module be cleaned?

Routine backwash and air scour should be conducted every 30–60 minutes. Chemical cleaning (CIP) is recommended every 2–4 weeks, depending on fouling rates.

4. What is the typical lifespan of the CPI-1030 UF Module?

With proper operation and maintenance, the membrane can last between 5 to 7 years.

5. Can this module handle high-turbidity water?

Yes, but pre-filtration (such as sand filters or cartridge filters) is recommended when feedwater turbidity exceeds 100 NTU.

6. What chemicals can be used for cleaning the membrane?

CIP protocols typically include sodium hypochlorite (oxidative cleaning), citric acid (scale removal), and sodium hydroxide (organic removal), within the safe pH range of 2–12.

7. What’s the optimal operating pressure for this module?

The ideal operating pressure is 0.1–0.2 MPa (1–2 bar), ensuring efficient filtration without exceeding transmembrane pressure limits.

8. Can the module be used in high-temperature environments?

The module operates safely up to 45°C. For temperatures above this, consult the manufacturer for compatibility and performance guarantees.

 

Ultrafiltrationmodules21.jpg


Conclusion

The CPI-1030 UF Module offers a superior, cost-effective, and fully compatible alternative to the LITREE CPI-1030. Whether you’re operating a large municipal facility or a compact industrial unit, this UF module ensures optimal performance, long service life, and excellent water quality.

With simple installation, easy maintenance, and a proven track record of reliability, the CPI-1030 is a smart upgrade for any system utilizing ultrafiltration technology. Its robust PVDF membrane structure ensures durability, while its high permeability and consistent filtrate quality make it a top choice for engineers and system integrators alike.


Get a FREE Quote

RELATED PRODUCTS

Leave a message

If you want to get more details about filter and filtration equipment, you can send E-mail to filter01@lefilter.com. You can consult our professional engineer and specialized sales team with leave a message in below form. We will contact with you ASAP. You also can visit our factory in Henan China.